__TENDER DATA RECORD: TPDDL/ENGG/ENQ/200001999/26\-27__
__One\-Year Rate Contract for Structured LAN Cabling, Active Network Hardware Installation & Fiber Maintenance__
__1\. TENDER INFORMATION & METADATA__
__TENDER\_RECORD\_VERSION__
1\.0
__TENDER\_ID__
TPDDL/ENGG/ENQ/200001999/26\-27
__TENDER\_TITLE__
One\-Year Rate Contract for Structured LAN Cabling, Active Network Hardware Installation & Fiber Maintenance
__TENDER\_TYPE__
CONTRACT
__ORGANIZATION\_TYPE__
CORPORATE
__ORGANIZATION__
Tata Power Delhi Distribution Limited \(TPDDL\)
__DEPARTMENT__
Information Technology, Telecommunications & Smart Grid Automation Wing
__CATEGORY__
IT
__SUBCATEGORY__
Enterprise LAN Infrastructure, Structured Cabling & Optical Fiber Splicing
__LOCATION__
Corporate Office, Zonal Offices, Customer Care Centres & Grid Substations across Delhi
__COUNTRY__
India
__STATE__
Delhi
__CITY__
New Delhi
__TENDER\_STATUS__
OPEN
__SOURCE\_VERIFIED__
YES
__LAST\_VERIFIED__
2026\-09\-20
__CORRIGENDUM\_AVAILABLE__
NO
__LATEST\_UPDATE__
Verified active as of 20\-Sep\-2026
__DUPLICATE\_CHECK__
PASSED
__DRIVE\_FOLDER\_TYPE__
PRIVATE\_TENDERS
__PUBLISH__
YES
__2\. TENDER DESCRIPTION__
Tata Power Delhi Distribution Limited invites bids under Ref\. TPDDL/ENGG/ENQ/200001999/26\-27 \(Rfx No\. 5000004468\) for a comprehensive one\-year Rate Contract for the design, turnkey laying, termination, OTDR testing, and ongoing maintenance of structured Local Area Network \(LAN\) passive and active infrastructure\. The works span corporate complexes, district offices, call centers, and 66/33kV grid substations supporting SCADA connectivity, advanced metering infrastructure \(AMI\), corporate intranet, and VoIP telecommunications\.
__3\. SCOPE OF WORK__
Supply and pulling of Category\-6A U/UTP and F/UTP 4\-pair LSZH copper cables through PVC conduits, raceways, and cable trays\.
Supply and installation of 24\-port / 48\-port modular patch panels, information outlets \(I/Os\), faceplates, and dual\-gang back boxes\.
Laying of 6\-core / 12\-core single\-mode armored optical fiber cables \(OFC\) between campus distribution blocks and network server rooms\.
Precision fusion splicing of fiber strands, optical distribution frame \(ODF\) termination, and bi\-directional OTDR link certification\.
Mounting and dressing of 9U to 42U network server racks, patch cord management, and UPS power socket provisioning\.
Permanent labeling of all network nodes, patch panel ports, and documentation of complete AutoCAD network topology schematics\.
__4\. FINANCIAL INFORMATION__
__ESTIMATED\_VALUE__
₹85,00,000
__CURRENCY__
INR
__EMD__
₹1,25,000
__TENDER\_FEE__
₹1,180
__5\. IMPORTANT DATES__
__PUBLICATION\_DATE__
2026\-09\-10
__PRE\_BID\_DATE__
2026\-09\-21 15:00
__CLARIFICATION\_DEADLINE__
2026\-09\-23 17:00
__SUBMISSION\_DEADLINE__
2026\-10\-01 15:00
__OPENING\_DATE__
2026\-10\-01 15:30
__CONTRACT\_START\_DATE__
2026\-10\-20
__CONTRACT\_DURATION__
12 Months \(Option for 12\-Month Extension\)
__6\. ELIGIBILITY & QUALIFICATIONS__
General Eligibility: Authorized network system integrators, structured cabling contractors, or IT infrastructure service providers; OEM authorization from tier\-1 structured cabling brands \(CommScope, Schneider, Legrand, or Panduit\); minimum 4 years operational track record delivering enterprise structured cabling for corporate campuses, data centers, or banking utilities\.
Experience Requirement: Successfully completed at least one structured LAN contract of value not less than ₹50 Lakh or two contracts of ₹30 Lakh each within the last 5 years\.
Turnover Requirement: Average annual financial turnover of at least ₹1\.2 Crores during the last three fiscal years\.
Technical Requirement: All copper cabling must pass TIA/EIA 568\-C\.2 Channel Testing \(Fluke DSX\-8000 certified reports\); deployed network engineers must hold OEM certified installer credentials\.
__7\. MSME & STARTUP INCENTIVES__
__MSME\_ELIGIBILITY__
YES
__STARTUP\_ELIGIBILITY__
NOT\_SPECIFIED
__SME\_SUITABILITY__
HIGH
__8\. REQUIRED DOCUMENTS__
Tender Fee payment receipt and EMD instrument
Valid OEM Authorization Certificate \(MAF\) for passive cabling components
Fluke Test calibration certificates and tester asset proof
GSTIN and PAN registration certificates
Client satisfaction letters from corporate or public sector clients
Signed Non\-Disclosure Agreement \(NDA\) and Tata Code of Conduct
__9\. CONTACT & PROCUREMENT AUTHORITY__
Contact Person: Head of IT Infrastructure Procurement
Email: it\.procurement@tatapower\-ddl\.com
Phone: \+91\-11\-66112345
Address: Tata Power Delhi Distribution Limited, Cennet Building, Netaji Subhash Place, Pitampura, New Delhi \- 110034
__10\. OFFICIAL SOURCES & DIRECT LINKS__
Official Source URL: https://www\.tatapower\-ddl\.com/vendor\-zone/tender\-corrigendum\-documents
Tender Document URL: https://www\.tatapower\-ddl\.com/vendor\-zone/tender\-corrigendum\-documents
Application / Portal URL: https://www\.tatapower\-ddl\.com/TPDDL\_Tender/Grid\.aspx
DISCLAIMER: TenderMan is an independent tender information platform\. All procurement notices, specifications, and bidding parameters are gathered from official public and private authority portals\. Prospective bidders must verify complete instructions and any corrigenda directly with the issuing authority prior to submission\.